How to Test Glassine Release Force for Your Application

Created on 06.20
Testing glassine release force is crucial for ensuring your adhesive product (like labels, tapes, or medical device components) performs reliably during dispensing and application. Here's a structured approach:
1. Define Your Test Parameters (The "How" Depends on "What"):
Application: How will the liner be peeled? (90° peel, 180° peel, high-speed automated dispensing?).
Adhesive: What type is used? (Acrylic, rubber, silicone? Permanent, removable?).
Glassine: What specific grade/coating does it have? (Silicone release level?).
Conditions: What temperature/humidity will application occur under? (ASTM D4332 conditioning is standard).
Acceptable Range: What force range ensures reliable release without adhesive transfer or liner splitting?
2. Select the Test Method & Equipment:
Standardized Methods:
ASTM D3330/D3330M: "Peel Adhesion of Pressure-Sensitive Tape". Most common, adaptable for liners.
FINAT Test Methods (e.g., FTM 10): Widely used in the label industry for release force.
PSTC Test Methods: Pressure Sensitive Tape Council standards.
Equipment:
Universal Tensile Tester: (Most versatile & accurate - Instron, MTS, Lloyd, Tinius Olsen). Essential for R&D & precise QC.
Dedicated Peel Tester: Simpler, often cheaper devices designed specifically for peel/release testing (e.g., ChemInstruments, Testing Machines Inc.).
Release Force Testers: Basic handheld or benchtop gauges measuring steady-state peel force. Good for spot checks in production.
3. Prepare Test Specimens:
Condition: Place adhesive/glassine samples in a controlled environment (typically 23°C ± 1°C / 73°F ± 2°F and 50% ± 5% RH) for 24+ hours before testing (ASTM D4332).
Cut Specimens: Use a precision cutter (e.g., JDC sample cutter) to create uniform strips (e.g., 1" / 25mm wide x 6-12" / 150-300mm long). Minimum 5-10 specimens per sample is recommended.
Laminate (if needed): Ensure the adhesive is firmly bonded to a rigid backing (e.g., polyester film, metal plate) using a standard roller (ASTM D3330 specifies 2 passes with a 4.5 lb / 2 kg rubber-covered steel roller at ~10 in/min). The glassine liner remains on top.
Prepare for Peel: Carefully separate the glassine liner from the adhesive backing for ~1-2 inches at one end to create a tab for gripping.
4. Conduct the Release Force Test:
Mount Specimen: Securely clamp the rigid backing plate in the tensile tester's lower jaw.
Attach Liner Tab: Clamp the glassine liner tab in the upper jaw. Ensure the liner is positioned correctly for the desired peel angle (90° and 180° are most common).
Set Parameters:
Peel Angle: 90° or 180° (Simulates application method).
Peel Speed: Critical! (Common speeds: 12 in/min / 300 mm/min or 24 in/min / 600 mm/min). Match your application speed if possible. Standardize this.
Data Acquisition Rate: High enough to capture force variations.
Run Test: Initiate the test. The machine peels the glassine liner away from the adhesive backing at the constant set speed and angle.
Record Data: The software records force (grams, ounces, Newtons) vs. distance (or time). Focus on the average steady-state peel force over the middle 50-80% of the peel distance. Note any spikes ("peaks") or drops ("valleys").
5. Analyze Results & Report:
Calculate the average release force (per unit width: oz/in, g/in, N/25mm, N/cm) for each specimen and the overall sample mean.
Calculate standard deviation and range to understand variability.
Report Peel Angle, Peel Speed, Test Conditions (Temp/RH), and Conditioning Time alongside the force values.
Visually inspect adhesive and liner for adhesive transfer (failure mode) or liner splitting after peel.
Key Considerations & Best Practices:
Consistency is Paramount: Control all variables meticulously (conditioning, specimen prep, speed, angle, operator technique).
Surface Contact: Avoid touching the adhesive or release surface with bare fingers.
Peel Initiation: The initial peak force to start peeling can be higher than steady-state. Focus analysis on the plateau.
Real-World Simulation: Test under conditions (especially temperature) close to actual application/storage.
Variability: Glassine release force can vary across a roll ("wind" variation). Test samples from different locations.
Aging: Test aged samples (accelerated aging per ASTM D3611 or real-time) to ensure release force stability.
Adhesive Transfer: This is a critical failure mode. Low release force can sometimes correlate with transfer, but not always. Visual inspection post-test is mandatory.
Equipment Recommendations:
R&D / Rigorous QC: Universal Tensile Tester with peel fixtures and environmental chamber.
Production QC: Dedicated benchtop peel/release tester or robust handheld gauge.
Spot Checks: Handheld release force gauge (ensure calibration and operator training).
By following this structured approach and standardizing your test parameters, you can reliably measure glassine release force and ensure it meets the critical requirements of your specific application.